INSTALLATION

The fender can be installed without changing the existing hardware in the platform and has a system that allows for final adjustment of the fender (+/- 1.5 M) in the splash zone, thus achieving efficiency and functionality.

 

RUBBER SPECIFICATIONS

PROPERTIES VALUE METHOD
1. Before aging:
  Hardness
Elongation
Tensile strength
Tear resistance
65° + 5° Shore A
300% min.
1900 PSI min.
280 lbs/inch
ASTM D-2240
ASTM D-412
ASTM D-412
ASTM D-624
2. After aging with hot air for 96 hours @ 70°C + -1°C
  Hardness
Elongation
Tensile strength
73° Shore A, maximum
-20% min.
-20% min.
ASTM D-2240
ASTM D-412
ASTM D-412
3. After aging with hot air for 22 hours @ 70°C + -1°C

  Compression coefficient 29% max. ASTM D-395
       
METALLIC STRUCTURE
PARTS MATERIAL
Main Pipe
Rim
Separator Flange
End Stops
Carbon Steel Pipe
Stainless Steel
Stainless Steel
Carbon Steel
   

[ Printer Friendly Version ]